Well_Test_Stage


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Well_Test_Stage
Entity Type Table
Description An individual, discrete event or period during a well test. Examples are blowdown, flowing, shut-in, etc. Some of the properties of the recovered fluid are also stored here.
Submodel Well_Testing
Entity Scope Project
Primary Key Id
Natural Key Well_Test_Id , Stage_Number , Existence_Kind , Version
Generalizations Wellsite_Activity , Activity , Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue Domain /
Measurement
DescriptionRequired /
Default
Type
Activity_Program_Id Activity_Program
Reference to the program during which the activity was performed. No
NUMBER(38)
Activity_State STRING64
NA
The current state, or status, of the activity. Activity state is a refinement of the lifecycle indicator Existence_Kind. For example, a drilling job whose Existence_Kind is "Actual" could have an activity state of "turning to the right", "suspended due to weather", or "tool makeup or breakdown". An activity whose Existence_Kind is "Required" could have State values like "under investigation", "proposed" and "AFE approved". Note: The valid list of activity states will vary from one kind of activity to another, so the values entered into this column are not validated via a lookup table. No
VARCHAR2(64)
Activity_Template_Id Activity_Template
The Activity is an activation of, and is characterized by the associated Activity_Template. No
NUMBER(38)
Average_BH_Pressure double
Pressure
The average of all the pressures measured at the bottomhole. No
NUMBER
Average_BH_Temperature double
Temperature
The average of all the temperatures measured at the bottomhole. No
NUMBER
Average_Casing_Pressure double
Pressure
The average of all the pressures measured between the casing and test tool (measured at the surface after a well has been shut in). No
NUMBER
Average_Casing_Temperature double
Temperature
The average of all the temperatures measured at the area between the casing and the test tool. No
NUMBER
Average_Flow_Rate double
Flowrate
The average flow rate of the reservoir fluid during the well test stage. I.e., the flow into the separator. No
NUMBER
Average_Hydro_Pressure double
Pressure
The average normal, predicted pressure for a given depth, or the pressure exerted per unit area by a column of freshwater from sea level to a given depth No
NUMBER
Average_Tubing_Pressure double
Pressure
The average of all the pressures measured within the tubing. No
NUMBER
Average_Tubing_Temperature double
Temperature
The average of all the temperatures measured within the tubing. No
NUMBER
BSW double
Percent
The percentage of Basic Sediment and Water in the flow stream. BSW is material coexisting with, yet foreign to, petroleum liquid. This foreign material includes free water and sediment and/or emulsified water and sediment. No
NUMBER
Base_Interval_MD double
Depth
Base depth of the interval being tested in the stage. No
NUMBER
Bottom_Hole_Choke_Size double
Cylinder_Diameter
The diameter of the choke at the bottomhole. No
NUMBER
Bottom_Hole_Choke_Size_UOM R_Unit
The unit of measure in which the bottom hole choke will be stored. No
VARCHAR2(64)
CGR double
Liquid_To_Gas_Ratio
The ratio of condensate volume to gas volume in the flow stream. No
NUMBER
Casing_Choke_Size double
Cylinder_Diameter
The diameter of the choke at the casing. No
NUMBER
Casing_Choke_Size_UOM R_Unit
The unit of measure in which the casing choke will be stored. No
VARCHAR2(64)
Duration double
Time
This is the duration of the well test stage. This is required when all that is known about a well test stage is the start date of the stage and the duration of the stage. No
NUMBER
End_Date DATE
NA
The date and time at which the activity will end or did end. For planned activities, this would be expected end date. No
DATE
Existence_Kind REF_EXISTENCE_KIND
NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
External_Reference STRING64
NA
A value that is used by an external organization to reference this activity. For example, if an external organization is hired to perform this activity, this column could be used to store the work order or purchase order number that organization uses to reference this activity. No
VARCHAR2(64)
Final_BH_Pressure double
Pressure
The final pressure measured at the bottomhole. No
NUMBER
Final_BH_Temperature double
Temperature
The final temperature measured at the bottomhole. No
NUMBER
Final_Casing_Pressure double
Pressure
The final pressure measured between the casing and test tool (measured at the surface after a well has been shut in). No
NUMBER
Final_Casing_Temperature double
Temperature
The final temperature measured of the area between the casing and the test tool. No
NUMBER
Final_Flow_Rate double
Flowrate
The final flow rate of the reservoir fluid during the well test stage. I.e., the flow into the separator. No
NUMBER
Final_Fluid_Level double
Depth
The final fluid level in the tubing No
NUMBER
Final_Hydro_Pressure double
Pressure
The final normal, predicted pressure for a given depth, or the pressure exerted per unit area by a column of freshwater from sea level to a given depth No
NUMBER
Final_Tubing_Pressure double
Pressure
The final pressure measured within the tubing. No
NUMBER
Final_Tubing_Temperature double
Temperature
The final temperature measured within the tubing. No
NUMBER
Fluid_State_Code R_Fluid_State
The Fluid State of the material at the time of the fluid recovery. This is defines as being the temperature and pressure state of a fluid (e.g., standard, dewpoint, and reservoir) No
VARCHAR2(64)
GLR double
Gas_To_Liquid_Ratio
The ratio of gas volume to liquid volume in the flow stream. No
NUMBER
GOR double
Gas_To_Liquid_Ratio
The ratio of gas volume to oil volume in the flow stream. No
NUMBER
GUID STRING128
NA
Globally Unique IDentifier for an instance of a class. This GUID is not generated by the database, but is the GUID used by the application on first access of this object. Use of this property is optional and completely under the control of application developers. No
VARCHAR2(128)
Id ID
No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Initial_BH_Pressure double
Pressure
The initial pressure measured at the bottom hole. No
NUMBER
Initial_BH_Temperature double
Temperature
The initial temperature measured at the bottom hole. No
NUMBER
Initial_Casing_Pressure double
Pressure
The initial pressure measured between the casing and test tool (measured at the surface after a well has been shut in). No
NUMBER
Initial_Casing_Temperature double
Temperature
The initial temperature measured at the area between the casing and the test tool. No
NUMBER
Initial_Flow_Rate double
Flowrate
The initial flow rate of the reservoir fluid during the well test stage. I.e., the flow into the separator. No
NUMBER
Initial_Fluid_Level double
Depth
The initial fluid level in the tubing No
NUMBER
Initial_Hydro_Pressure double
Pressure
The initial normal, predicted pressure for a given depth, or the pressure exerted per unit area by a column of freshwater from sea level to a given depth No
NUMBER
Initial_Tubing_Pressure double
Pressure
The initial pressure measured within the tubing. No
NUMBER
Initial_Tubing_Temperature double
Temperature
The initial temperature measured within the tubing. No
NUMBER
Insert_Date DATE
NA
Date the entity was created in the repository No
DATE
Insert_User STRING64
NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Internal_Reference STRING64
NA
A value that is used internally within the organization to reference this activity. No
VARCHAR2(64)
Name ENTITY_NAME
NA
The name given to any object or data item, e.g. Name of Well, Name of Field, etc. No
VARCHAR2(255)
Orifice_Size double
Cylinder_Diameter
The size of the constriction (orifice plate) present in a gas meter when the well test was recorded. No
NUMBER
Original_Source STRING64
NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Produced_By STRING64
NA
ID of the activity that was executing when the entity was created, for data created programmatically. No
VARCHAR2(64)
Produced_GLR double
Gas_To_Liquid_Ratio
The ratio of (Total Gas Volume - Gas Lift Injected) to Total Liquid Volume in the flow stream. No
NUMBER
Produced_GOR double
Gas_To_Liquid_Ratio
The ratio of (Total Gas Volume - Gas Lift Injected) to Total Oil Volume in the flow stream. No
NUMBER
Productive_Duration double
Time
The amount of time the specified material was being produced during the well test stage No
NUMBER
Purpose STRING255
NA
A description of purpose of the activity or its stage No
VARCHAR2(255)
Remarks STRING2000
NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int
No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Sand_Cut double
High_Concentration
The ratio of sand volume to total liquid in the flow stream. It is normally defined as Sand/Total Fluid Volume. No
NUMBER
Separator_Choke_Size double
Cylinder_Diameter
The diameter of the choke at the separator. No
NUMBER
Separator_Choke_Size_UOM R_Unit
The unit of measure in which the separator choke will be stored. No
VARCHAR2(64)
Source STRING64
NA
Name of the person or organization responsible for this entity"s E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Stage_Number int
No_Unit
A non-intelligent sequence number that identifies this test stage within a well test. Yes
NUMBER(10)
Start_Date DATE
NA
The date and time at which the activity will start or did start. For planned activities, this would be expected start date. No
DATE
Stroke_Rate double
Frequency
The pumping stroke rate. Describes as strokes per minute. This is a denormalization of data that is usually stored in the Pumping_Unit_Oper_Pty_Set class No
NUMBER
Time_Offset double
Time
The time offset from the start of the program that this activity is scheduled to start at. This is normally used while planning a job. No
NUMBER
Time_To_Surface double
Time
The amount of time from the initiation of the well test stage for the reservoir fluid recovered to reach the surface. No
NUMBER
Top_Interval_MD double
Depth
Top depth of the interval being tested in the stage. No
NUMBER
Transient_Period R_Transient_Period
Indicates whether the activity is executed daily, monthly, on demand, etc. No
VARCHAR2(64)
Triggering_Event_Id Event
The identifier of the event that triggered the start of this activity. Events can trigger activities. For example, an explosion event could trigger a firefighting activity. Note that this value should not conflict with, or be confused with, the value in Activity_Status.Triggering_Event. No
NUMBER(38)
Tubing_Choke_Size double
Cylinder_Diameter
The diameter of the choke at the wellhead. No
NUMBER
Tubing_Choke_Size_UOM R_Unit
The unit of measure in which the tubing choke will be stored. No
VARCHAR2(64)
Update_Date DATE
NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64
NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Version STRING255
NA
The form or variant of the entity. Yes
1
VARCHAR2(255)
WCR double
Liquid_To_Liquid_Ratio
The ratio of water volume to condensate volume in the flow stream. No
NUMBER
WGR double
Liquid_To_Gas_Ratio
The ratio of water volume to gas volume in the flow stream. No
NUMBER
WOR double
Liquid_To_Liquid_Ratio
The ratio of water volume to oil volume in the flow stream. No
NUMBER
Water_Cut double
Liquid_To_Liquid_Ratio
The ratio of water volume to total liquid volume in the flow stream. It is normally defined as Water/(Water + Oil). No
NUMBER
Well_Test_Id Well_Test
The identifier of the well test to which this stage belongs. Yes
NUMBER(38)
Well_Test_Stage_Type R_Well_Test_Stage
A value that represents the type of well test stage. Examples are Shut-in, Blowdown, flowing, etc. Yes
VARCHAR2(64)


Referenced By

[Previous] [Next] [Top]
From EntityLinkDescriptionImplementation TechniqueRequired
Fluid_Sample Well_Test_Stage The identifier of the well test stage that may have been used to acquire the fluid. Cascade No
Production_Test_DOV Well_Test_Stage READ ONLY: Unique identifier for the Well Test Stage. Cascade No
Well_Test_Fluid_Recovery Well_Test_Stage The identifier of the well test stage during which the fluid was recovered. Cascade Yes
Well_Test_Interpretation Well_Test_Stage The identifier of the well test stage whose data is being interpreted via this interpretation. An analysis can be performed either for a well test or a well test stage. Nullify No
Well_Test_Site Well_Test_Stage The identifier of the well_test_stage for which the site(s) is being defined. Cascade No
Well_Test_Trace Well_Test_Stage The identifier of the well test stage during which the trace measurements were recorded. Cascade No


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Activity_Template Activity_Template _ Restrict No
Transient_Period R_Transient_Period _ Restrict No
Bottom_Hole_Choke_Size_UOM R_Unit The unit of measure in which the bottom hole choke will be stored. Restrict No
Casing_Choke_Size_UOM R_Unit The unit of measure in which the casing choke will be stored. Restrict No
Fluid_State_Code R_Fluid_State The Fluid State of the material at the time of the fluid recovery. This is defines as being the temperature and pressure state of a fluid (e.g., standard, dewpoint, and reservoir) Restrict No
Separator_Choke_Size_UOM R_Unit The unit of measure in which the separator choke will be stored. Restrict No
Activity_Program Activity_Program _ Restrict No
Well_Test Well_Test The identifier of the well test to which this stage belongs. Cascade Yes
Well_Test_Stage_Type R_Well_Test_Stage A value that represents the type of well test stage. Examples are Shut-in, Blowdown, flowing, etc. Restrict Yes
Super_Activity Activity _ Assoc to One No
Fulfilled_Activity Activity _ Assoc to Many No
Triggering_Event Event _ Nullify No
Tubing_Choke_Size_UOM R_Unit The unit of measure in which the tubing choke will be stored. Restrict No


[Seabed Objects] [Entities in Schema Seabed] [Index]

Copyright © 2009 Schlumberger. All rights reserved.