Sucker_Rod


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Sucker_Rod
Entity Type Table
Description A sucker rod is the connecting link between the surface pumping unit and the subsurface pump, which is located at or near the bottom of the oil well.
Submodel Artificial_Lift
Entity Scope Project
Primary Key Id
Natural Key
Generalizations Tubular , Tracked_Facility , Facility , Entity , IT_Object , Tracked_Object
Specializations


Columns

[Previous] [Next] [Top]
NameValue Domain /
Measurement
DescriptionRequired /
Default
Type
Absolute_Roughness double
Length
The absolute roughness of the inside wall of the tubular No
NUMBER
Address_Id Address
The address of the Tracked Facility No
NUMBER(38)
Axial_Stiffness double
Spring_Stiffness
A measure of the inflexibility of a tubular in an axial plane No
NUMBER
Bend_Stiffness double
Spring_Stiffness
A measure of the inflexibility of a tubular in a longitudinal plane No
NUMBER
Burst_Pressure double
Pressure
Burst Pressure of the tubular No
NUMBER
Catalog_Cost double
No_Unit
The catalog cost of the piece of equipment or facility expressed in the currency denoted by the attribute Catalog_Currency No
NUMBER
Catalog_Currency R_Currency
The currency in which the catalog cost is expressed. No
VARCHAR2(64)
Catalog_Number STRING64
NA
A catalog or part number for a facility. No
VARCHAR2(64)
Coating_Desc STRING64
NA
A description of the coating applied to the tubular No
VARCHAR2(64)
Collapse_Pressure double
Pressure
Collapse pressure No
NUMBER
Compressive_Strength double
Pressure
Compressive Strength of tubular No
NUMBER
Displacement_Volume double
Volume_Per_Length
The cross-sectional area of steel (or other material if the tubular is not made of steel) in the tubular expressed in units of volume per unit length. No
NUMBER
Drift_Diameter double
Cylinder_Diameter
Largest diameter of a perfect cylinder that can fit into the pipe. Because a pipe is slightly oval the drift diameter is always smaller than the quoted inner diameter. The drift diameter is used to know if a given pipe will run into a pipe. No
NUMBER
Existence_Kind REF_EXISTENCE_KIND
NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
Facility_Equipment_Flag CODE
NA
A flag to denote whether a given facility should be treated as a facility (F), a piece of equipment (E) or both (B). A facility labeled as F represents a role (e.g. ESP) played by physical piece(s) of equipment and would not have attributes like serial number, manufacturer etc. It can be related to the physical pieces(s) of equipment using Facility_Composition. The individual physical pieces can be replaced if they need to be, without changing the facility. A Facility labeled as E represents a physical piece of equipment (e.g. Drill Pipe) which is normally used in the context of an activity and would not be permanently installed. A facility labeled as B represents both a physical piece of equipment as well as the role played by it. If this kind of Facility is connected in the network and stops working and needs to be replaced, then all connections to this Facility are expired and new connections are made to the replacement facility. No
VARCHAR2(64)
Fatigue_Endurance_Limit double
Stress
The maximum stress below which the tubular could presumably endure an infinite number of cycles. No
NUMBER
Fishneck_Inside_Diameter double
Cylinder_Diameter
The inside diameter of the fishneck. No
NUMBER
Fishneck_Length double
Length
Fishing neck length. This is defined as being the distance from the seal face to the location of any section change. No
NUMBER
Fishneck_Outside_Diameter double
Cylinder_Diameter
The inside diameter of the fishneck. No
NUMBER
GUID STRING128
NA
Globally Unique IDentifier for an instance of a class. This GUID is not generated by the database, but is the GUID used by the application on first access of this object. Use of this property is optional and completely under the control of application developers. No
VARCHAR2(128)
Guide_Description STRING64
NA
Description of the guides No
VARCHAR2(64)
Guide_Material STRING64
NA
Material of which the guide is made of No
VARCHAR2(64)
Guide_Size double
Cylinder_Diameter
Size of the guides No
NUMBER
Guides_Per_Rod_Count int
No_Unit
Number of guides in the rod No
NUMBER(10)
Heavyweight_Flag boolean
NA
A flag to denote whether or not the tubular is classified as a "Heavyweight" tubular or not No
NUMBER(1)
Hydrostatic_Test_Pressure double
Pressure
The nominal test pressure that a tubular can safely hold No
NUMBER
Id ID
No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Insert_Date DATE
NA
Date the entity was created in the repository No
DATE
Insert_User STRING64
NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Inside_Diameter double
Cylinder_Diameter
Actual Inside diameter of an entity, such as an item of drill string equipment. In the absence of the actual value the catalog value should be used No
NUMBER
Inventory_Id STRING64
NA
The formal identification for a piece of equipment, a serial number or inventory ID No
VARCHAR2(64)
Joint_Count int
No_Unit
The number of joints of tubular goods. No
NUMBER(10)
Length double
Length
Actual length of the drill string component No
NUMBER
Linear_Weight double
Mass_Per_Length
Weight of an equipment item per unit length; e.g. Casing weight, pipe weight, cable weight, etc. No
NUMBER
Manufacture_Date DATE
NA
Date of manufacturing the facility. No
DATE
Manufacturer STRING64
NA
Name of the business associate who manufactured the item. No
VARCHAR2(64)
Material_Type STRING64
NA
The primary material type of facility. No
VARCHAR2(64)
Max_Dog_Leg_Severity double
Well_Curvature
The maximum dog leg severity for the tubular. No
NUMBER
Max_Make_Up_Torque double
High_Torque
The torque above which you have over-torqued (damaged the threads). No
NUMBER
Max_Outside_Diameter double
Cylinder_Diameter
Maximum external diameter of the tubular. The Outside diameter is the external diameter of the body of the tubular No
NUMBER
Min_Make_Up_Torque double
High_Torque
The minimum torque required to make up the joint to meet the leak resistance spec. No
NUMBER
Model_Name STRING64
NA
Name of a model or version of some entity; for equipment, it may coincide with the trade name. No
VARCHAR2(64)
Name ENTITY_NAME
NA
The name given to any object or data item, e.g. Name of Well, Name of Field, etc. No
VARCHAR2(255)
Non_Magnetic_Flag boolean
NA
A flag indicating whether the equipment is made with non magnetic material No
NUMBER(1)
Original_Source STRING64
NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Outside_Diameter double
Cylinder_Diameter
Actual Outside diameter of the Equipment. For a tubular, it is the outside diameter of the body. In the absence of the actual value the catalog value should be used No
NUMBER
Polished_Flag boolean
NA
A flag to denote whether the Sucker Rod is polished or not. A value of 1 means that the rod is a polished rod, 0 means it is not No
NUMBER(1)
Produced_By STRING64
NA
ID of the activity that was executing when the entity was created, for data created programmatically. No
VARCHAR2(64)
Remarks STRING2000
NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int
No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Serial_Number STRING64
NA
The serial number placed on a piece of equipment. No
VARCHAR2(64)
Source STRING64
NA
Name of the person or organization responsible for this entity"s E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Steel_Grade STRING64
NA
Grade used to qualify the characteristics of the steel. For tubular, grade determines the minimum yield strength and thus the burst and collapse pressures. The grade can be either defined by the supplier or defined by the API. No
VARCHAR2(64)
Tensile_Strength double
Pressure
Maximum tensile strength of the item No
NUMBER
Thread_Lock_Flag boolean
NA
A flag to indicate whether or not thread locks have been used No
NUMBER(1)
Torsional_Stiffness double
Spring_Stiffness
A measure of the inflexibility of a tubular around its longitudinal axis No
NUMBER
Torsional_Strength double
Torque
Maximum torsional strength of the item No
NUMBER
Update_Date DATE
NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64
NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Used_Class STRING64
NA
Used Classification (New, used or reconditioned) No
VARCHAR2(64)
VME_Rating double
No_Unit
Von Mises Equivalent Stress Rating No
NUMBER
Vendor_Id Company
The company from which the facility was purchased. No
NUMBER(38)
Version STRING255
NA
The form or variant of the entity. Yes
1
VARCHAR2(255)
Wall_Thickness double
Cylinder_Diameter
The actual thickness of the wall of the tubular. In the absence of the actual value the catalog value should be used No
NUMBER
Weight double
Force
The weight of the Tubular No
NUMBER


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Address Address _ Nullify No
Catalog_Currency R_Currency _ Restrict No
Vendor Company _ Nullify No


[Seabed Objects] [Entities in Schema Seabed] [Index]

Copyright © 2009 Schlumberger. All rights reserved.