| Name | Fluid_Pumping_Detail |
|---|---|
| Entity Type | Table |
| Description | Detail information for each pumping activity. |
| Submodel | WS_Material |
| Entity Scope | Project |
| Primary Key | Id |
| Natural Key | |
| Generalizations | Entity , IT_Object , Tracked_Object |
| Specializations |
| Name | Value Domain / Measurement | Description | Required / Default | Type |
|---|---|---|---|---|
| Avg_Pumping_Pressure | double Pressure |
The average pressure recorded during the activity | No |
NUMBER |
| Avg_Pumping_Rate | double Flowrate |
The average rate of pumping observed during the pumping activity | No |
NUMBER |
| End_Date | DATE NA |
The date and time at which the pumping of this fluid will stop or did stop. | No |
DATE |
| Excess_Volume_Method | STRING32 NA |
The method to determine the excess volume | No |
VARCHAR2(32) |
| Excess_Volume_Percent | double Percent |
Percentage of excess volume included in the volume pumped. | No |
NUMBER |
| Existence_Kind | REF_EXISTENCE_KIND NA |
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. | Yes Actual |
VARCHAR2(64) |
| Final_Pumping_Pressure | double Pressure |
The final pressure recorded during the activity | No |
NUMBER |
| Final_Pumping_Rate | double Flowrate |
The final rate of pumping observed during the pumping activity | No |
NUMBER |
| Fluid_Bottom_MD | double Depth |
For fluids pumped into the borehole this is the measured depth of the bottom of the fluid. For example if the fluid is a lead slurry it is the measured depth of the bottom of the tail slurry. | No |
NUMBER |
| Fluid_Length | double Length |
The length of the fluid column being used during borehole activity. Example: the cushion fluid length for a well test. | No |
NUMBER |
| Fluid_Pumping_Schedule_Id | Fluid_Pumping_Schedule |
Which schedule the detail record relates to | Yes |
NUMBER(38) |
| Fluid_Top_MD | double Depth |
For fluids pumped into the borehole this is the measured depth of the top of the fluid. For example if the fluid is a lead slurry it is the measured depth of the top of the lead slurry. | No |
NUMBER |
| GUID | STRING128 NA |
Globally Unique IDentifier for an instance of a class. This GUID is not generated by the database, but is the GUID used by the application on first access of this object. Use of this property is optional and completely under the control of application developers. | No |
VARCHAR2(128) |
| Id | ID No_Unit |
Unique identifier for this entity. | Yes |
NUMBER(38) |
| In_Well_Volume | double Volume |
The volume of fluid that remains in the well after pumping is complete. | No |
NUMBER |
| Initial_Pumping_Pressure | double Pressure |
The initial pressure recorded during the activity | No |
NUMBER |
| Initial_Pumping_Rate | double Flowrate |
The initial rate of pumping observed during the pumping activity | No |
NUMBER |
| Injection_Temperature | double Temperature |
The temperature of the fluid being injected | No |
NUMBER |
| Insert_Date | DATE NA |
Date the entity was created in the repository | No |
DATE |
| Insert_User | STRING64 NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
| Lost_Volume | double Volume |
Lost Volume of fluid during the pumping operation | No |
NUMBER |
| Max_Pumping_Pressure | double Pressure |
The maximum pressure recorded during the activity | No |
NUMBER |
| Max_Pumping_Rate | double Flowrate |
The maximum rate of pumping observed during the pumping activity | No |
NUMBER |
| Min_Pumping_Pressure | double Pressure |
The minimum pressure recorded during the activity | No |
NUMBER |
| Min_Pumping_Rate | double Flowrate |
The minimum rate of pumping observed during the pumping activity | No |
NUMBER |
| Name | ENTITY_NAME NA |
The name given to any object or data item, e.g. Name of Well, Name of Field, etc. | No |
VARCHAR2(255) |
| Original_Source | STRING64 NA |
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" | No |
VARCHAR2(64) |
| Plug_Pumped_Flag | boolean NA |
Was a plug pumped along with this fluid movement | No |
NUMBER(1) |
| Produced_By | STRING64 NA |
ID of the activity that was executing when the entity was created, for data created programmatically. | No |
VARCHAR2(64) |
| Pumped_Volume | double Volume |
The Volume of fluid pumped during this part of the schedule | No |
NUMBER |
| Pumping_Time | double Minute |
The time taken to pump the fluid | No |
NUMBER |
| Purpose | STRING32 NA |
The purpose of the fluid being pumped, Packer, Displacement... | No |
VARCHAR2(32) |
| Remarks | STRING2000 NA |
Any type of remarks added to an entity instance. | No |
VARCHAR2(2000) |
| Returned_Volume | double Volume |
The volume of fluid returned to the surface | No |
NUMBER |
| Reversed_Volume | double Volume |
Volume of Slurry Reversed out of Hole | No |
NUMBER |
| SDAT_Label | int No_Unit |
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. | No |
NUMBER(10) |
| Sequence_Number | int No_Unit |
A sequence number to provide an order to pumping schedule when dates and times are not available | Yes 1 |
NUMBER(10) |
| Source | STRING64 NA |
Name of the person or organization responsible for this entity"s E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. | No |
VARCHAR2(64) |
| Start_Date | DATE NA |
The date and time at which the pumping of this fluid will start or did start. | No |
DATE |
| Update_Date | DATE NA |
Date of the most-recent modification to the entity. | No |
DATE |
| Update_User | STRING64 NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
| Version | STRING255 NA |
The form or variant of the entity. | Yes 1 |
VARCHAR2(255) |
| Link | To Entity | Description | Implementation Technique | Required |
|---|---|---|---|---|
| Fluid_Pumping_Schedule | Fluid_Pumping_Schedule | Which schedule the detail record relates to | Cascade | Yes |
| Fluid | Wellsite_Fluid | The fluid pumped by the pumping schedule. A fluid pumping detail record without a fluid associated to it is a wait operation | Assoc to One | No |