| Name | Facility_Connector |
|---|---|
| Entity Type | Table |
| Description | A device or mechanism used to connect one facility to another. |
| Submodel | Facility |
| Entity Scope | Project |
| Primary Key | Id |
| Natural Key | |
| Generalizations | Entity , IT_Object , Tracked_Object |
| Specializations |
| Name | Value Domain / Measurement | Description | Required / Default | Type |
|---|---|---|---|---|
| Attachment_Pattern | STRING64 NA |
The attachment pattern for the tubular accessory | No |
VARCHAR2(64) |
| Compatible_Connection | CODE NA |
A connector of a different type that will successfully mate with this connector | No |
VARCHAR2(64) |
| Connector_Type | STRING64 NA |
Type of connector used at a port (e.g., threaded, flanged) | No |
VARCHAR2(64) |
| Critical_Cross_Section | double Area |
The critical cross section of a connector. Used for calculating bending stiffness ratio. | No |
NUMBER |
| Drift_Diameter | double Cylinder_Diameter |
The largest diameter object that can be successfully passed through the connector | No |
NUMBER |
| Existence_Kind | REF_EXISTENCE_KIND NA |
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. | Yes Actual |
VARCHAR2(64) |
| Facility_Id | Facility |
Reference to the facility for which the connector has been defined. | Yes |
NUMBER(38) |
| Facility_Tbl | Meta_Entity |
Facility type | Yes |
VARCHAR2(30) |
| GUID | STRING128 NA |
Globally Unique IDentifier for an instance of a class. This GUID is not generated by the database, but is the GUID used by the application on first access of this object. Use of this property is optional and completely under the control of application developers. | No |
VARCHAR2(128) |
| Gender | STRING1 NA |
Gender of connector (e.g., BOX vs. PIN, MALE vs. FEMALE) | No |
VARCHAR2(1) |
| Hydrostatic_Test_Pressure | double Pressure |
The hydrostatic pressure rating of this connector | No |
NUMBER |
| Id | ID No_Unit |
Unique identifier for this entity. | Yes |
NUMBER(38) |
| Insert_Date | DATE NA |
Date the entity was created in the repository | No |
DATE |
| Insert_User | STRING64 NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
| Inside_Diameter | double Cylinder_Diameter |
Actual Inside diameter of a connector (e.g., tool joint or flange). In the absence of the actual value the catalog value should be used. | No |
NUMBER |
| Length | double Length |
Length of the connector | No |
NUMBER |
| Linear_Weight | double Mass_Per_Length |
Weight of a connector such as a tool joint per unit length | No |
NUMBER |
| Material_Grade | CODE NA |
The grade of the material used in the construction of this connector | No |
VARCHAR2(64) |
| Max_Make_Up_Torque | double High_Torque |
The torque above which you have over-torqued (damaged the threads). | No |
NUMBER |
| Min_Make_Up_Torque | double High_Torque |
The minimum torque required to make up the joint to meet the leak resistance spec. | No |
NUMBER |
| Name | ENTITY_NAME NA |
The name given to any object or data item, e.g. Name of Well, Name of Field, etc. | No |
VARCHAR2(255) |
| Original_Source | STRING64 NA |
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" | No |
VARCHAR2(64) |
| Outside_Diameter | double Cylinder_Diameter |
Actual Outside diameter of a connector (e.g., tool joint or flange). In the absence of the actual value the catalog value should be used. | No |
NUMBER |
| Produced_By | STRING64 NA |
ID of the activity that was executing when the entity was created, for data created programmatically. | No |
VARCHAR2(64) |
| Remarks | STRING2000 NA |
Any type of remarks added to an entity instance. | No |
VARCHAR2(2000) |
| SDAT_Label | int No_Unit |
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. | No |
NUMBER(10) |
| Source | STRING64 NA |
Name of the person or organization responsible for this entity"s E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. | No |
VARCHAR2(64) |
| Standardization_Name | CODE NA |
The standard body that holds the standard for this connector | No |
VARCHAR2(64) |
| Stress_Relief_Flag | boolean NA |
A flag to indicate whether or not a Stress Relief groove was provided. A Stress Relief groove is a groove at the shoulder of the pin to relieve excessive connection stress, increase connection flexibility, and reduce fatigue. | No |
NUMBER(1) |
| Tensile_Strength | double Strength |
The Tensile strength of this connector | No |
NUMBER |
| Thread_Category | CODE NA |
A further sub-classification of the thread type E.g. Long Thread, Short Thread | No |
VARCHAR2(64) |
| Thread_Inside_Diameter | double Cylinder_Diameter |
Actual inside diameter of the first threaded connection. | No |
NUMBER |
| Thread_Outside_Diameter | double Cylinder_Diameter |
Actual outside diameter of the first threaded connection. Often called size, e.g., 2 1/4 | No |
NUMBER |
| Thread_Type | R_Thread |
The thread type of the facility connector | No |
VARCHAR2(64) |
| Torsional_Strength | double Strength |
The TORSIONAL strength of this connector | No |
NUMBER |
| Update_Date | DATE NA |
Date of the most-recent modification to the entity. | No |
DATE |
| Update_User | STRING64 NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
| Upset_Type | CODE NA |
A description of whether the upset (increase in thickness) of the pipe at the tool joint is External, Internal or both | No |
VARCHAR2(64) |
| Version | STRING255 NA |
The form or variant of the entity. | Yes 1 |
VARCHAR2(255) |
| Weight | double Force |
The weight of the connector | No |
NUMBER |
| Cardinality | Entity |
|---|---|
| Many | Connector_Condition |
| From Entity | Link | Description | Implementation Technique | Required |
|---|---|---|---|---|
| Facility_Connection | To_Connector | Reference to the connector as the part that has been connected to. | Cascade | No |
| Facility_Connection | From_Connector | Reference to the connector as the part that has been connected from. | Cascade | No |
| Link | To Entity | Description | Implementation Technique | Required |
|---|---|---|---|---|
| Facility | Facility | Reference to the facility for which the connector has been defined. | Cascade | Yes |
| Thread_Type | R_Thread | The thread type of the facility connector | Restrict | No |