| Name | ESP_Oper_Pty_Set |
|---|---|
| Entity Type | Table |
| Description | The operating properties of an ESP. When an ESP is placed in the borehole is ceases to be a collection of components and becomes more of a system. These are the properties of the system. |
| Submodel | Artificial_Lift |
| Entity Scope | Project |
| Primary Key | Id |
| Natural Key | ESP_Id , Start_Date , Existence_Kind , Version |
| Generalizations | Operating_Property_Set , Entity , IT_Object , Tracked_Object |
| Specializations |
| Name | Value Domain / Measurement | Description | Required / Default | Type |
|---|---|---|---|---|
| A_To_B_Resistance | double Electric_Resistance |
The resistance reading from Phase A to Phase B of the ESP system | No |
NUMBER |
| A_To_Ground_Resistance | double Electric_Resistance |
The resistance reading from Phase A to ground of the ESP system | No |
NUMBER |
| Application_HP | double NA |
The horsepower of the motor system for a given application. This is usually calculated from the values of the application HP of the component motors. | No |
NUMBER |
| B_To_C_Resistance | double Electric_Resistance |
The resistance reading from Phase B to Phase C of the ESP system | No |
NUMBER |
| B_To_Ground_Resistance | double Electric_Resistance |
The resistance reading from Phase B to ground of the ESP system | No |
NUMBER |
| C_To_A_Resistance | double Electric_Resistance |
The resistance reading from Phase C to Phase A of the ESP system | No |
NUMBER |
| C_To_Ground_Resistance | double Electric_Resistance |
The resistance reading from Phase C to ground of the ESP system | No |
NUMBER |
| Cable_A_To_B_Resistance | double Electric_Resistance |
The resistance reading from Phase A to Phase B of the ESP Cable | No |
NUMBER |
| Cable_A_To_Ground_Resist | double Electric_Resistance |
The resistance reading from Phase A to ground of the ESP Cable | No |
NUMBER |
| Cable_B_To_C_Resistance | double Electric_Resistance |
The resistance reading from Phase B to Phase C of the ESP Cable | No |
NUMBER |
| Cable_B_To_Ground_Resist | double Electric_Resistance |
The resistance reading from Phase B to ground of the ESP Cable | No |
NUMBER |
| Cable_C_To_A_Resistance | double Electric_Resistance |
The resistance reading from Phase C to Phase A of the ESP Cable | No |
NUMBER |
| Cable_C_To_Ground_Resist | double Electric_Resistance |
The resistance reading from Phase C to ground of the ESP Cable | No |
NUMBER |
| Calibration_Full_Scale_Ref | double No_Unit |
The full scale reference value for the monitoring system installed in a well | No |
NUMBER |
| Calibration_Zero_Ref | double No_Unit |
The zero reference value for the monitoring system installed in a well | No |
NUMBER |
| Current_Leakage | double Electric_Current |
A measure of the current leakage from the ESP | No |
NUMBER |
| Discharge_Pressure | double Pressure |
The pressure measured at the discharge point of the ESP. | No |
NUMBER |
| Discharge_Temperature | double Temperature |
The temperature measured at the discharge point of the ESP. | No |
NUMBER |
| Discharge_Vibration | double Gravity |
The vibration of the ESP system as measured at the outlet by a downhole sensor | No |
NUMBER |
| Discharge_Vibration_X | double Gravity |
The vibration of the ESP system as measured at the outlet by a downhole sensor in the X plane | No |
NUMBER |
| Discharge_Vibration_Y | double Gravity |
The vibration of the ESP system as measured at the outlet by a downhole sensor in the Y plane | No |
NUMBER |
| Discharge_Vibration_Z | double Gravity |
The vibration of the ESP system as measured at the outlet by a downhole sensor in the Z plane | No |
NUMBER |
| ESP_Id | ESP |
The ESP system to which the operating properties belong | Yes |
NUMBER(38) |
| End_Date | DATE NA |
End date and time of the validity of these properties | No |
DATE |
| Existence_Kind | REF_EXISTENCE_KIND NA |
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. | Yes Actual |
VARCHAR2(64) |
| Flowing_Downhole_Pressure | double Pressure |
Flowing downhole pressure reading. | No |
NUMBER |
| GUID | STRING128 NA |
Globally Unique IDentifier for an instance of a class. This GUID is not generated by the database, but is the GUID used by the application on first access of this object. Use of this property is optional and completely under the control of application developers. | No |
VARCHAR2(128) |
| Id | ID No_Unit |
Unique identifier for this entity. | Yes |
NUMBER(38) |
| Insert_Date | DATE NA |
Date the entity was created in the repository | No |
DATE |
| Insert_User | STRING64 NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
| Intake_Pressure | double Pressure |
The pressure measured at the intake of the ESP. | No |
NUMBER |
| Intake_Temperature | double Temperature |
The temperature measured at the intake of the ESP. | No |
NUMBER |
| Load_Voltage | double Electric_Potential |
The voltage of the system with the system running | No |
NUMBER |
| Measuring_Activity_Id | Generic_Wellsite_Activity |
The activity that measured the ESP operating properties | No |
NUMBER(38) |
| Motor_A_To_B_Resistance | double Electric_Resistance |
The resistance reading from Phase A to Phase B of the motor assembly | No |
NUMBER |
| Motor_A_To_Ground_Resist | double Electric_Resistance |
The resistance reading from Phase A to ground of the motor assembly | No |
NUMBER |
| Motor_B_To_C_Resistance | double Electric_Resistance |
The resistance reading from Phase B to Phase C of the motor assembly | No |
NUMBER |
| Motor_B_To_Ground_Resist | double Electric_Resistance |
The resistance reading from Phase B to ground of the motor assembly | No |
NUMBER |
| Motor_C_To_A_Resistance | double Electric_Resistance |
The resistance reading from Phase C to Phase A of the motor assembly | No |
NUMBER |
| Motor_C_To_Ground_Resist | double Electric_Resistance |
The resistance reading from Phase C to ground of the motor assembly | No |
NUMBER |
| Motor_Temperature | double Temperature |
The temperature of the motor as measured by a downhole sensor | No |
NUMBER |
| Motor_Vibration | double Gravity |
The vibration of the ESP system as measured at the motor by a downhole sensor | No |
NUMBER |
| Motor_Vibration_X | double Gravity |
The vibration of the ESP system as measured at the motor by a downhole sensor in the X plane | No |
NUMBER |
| Motor_Vibration_Y | double Gravity |
The vibration of the ESP system as measured at the motor by a downhole sensor in the Y plane | No |
NUMBER |
| Motor_Vibration_Z | double Gravity |
The vibration of the ESP system as measured at the motor by a downhole sensor in the Z plane | No |
NUMBER |
| Name | ENTITY_NAME NA |
The name given to any object or data item, e.g. Name of Well, Name of Field, etc. | No |
VARCHAR2(255) |
| No_Load_Voltage | double Electric_Potential |
The voltage of the system with the system not running | No |
NUMBER |
| Original_Source | STRING64 NA |
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" | No |
VARCHAR2(64) |
| Produced_By | STRING64 NA |
ID of the activity that was executing when the entity was created, for data created programmatically. | No |
VARCHAR2(64) |
| Pump_Up_Time | double Time |
The time taken for the fluid to reach the surface | No |
NUMBER |
| Remarks | STRING2000 NA |
Any type of remarks added to an entity instance. | No |
VARCHAR2(2000) |
| Rotational_Phasing_Desc | CODE NA |
The description of the rotational phasing of the power for an ESP system. This can be "ABC" or "CBA" | No |
VARCHAR2(64) |
| SDAT_Label | int No_Unit |
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. | No |
NUMBER(10) |
| Settled_Current | double Electric_Current |
The settled system current with a constant pump load on the motor | No |
NUMBER |
| Settling_Time | double Time |
The time take for the system to establish a settled state | No |
NUMBER |
| Source | STRING64 NA |
Name of the person or organization responsible for this entity"s E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. | No |
VARCHAR2(64) |
| Start_Count | int No_Unit |
The number of times this ESP has been "started" during this period | No |
NUMBER(10) |
| Start_Current | double Electric_Current |
The start current for the system. Indicates the load on the motor | No |
NUMBER |
| Start_Date | DATE NA |
Start date and time of the validity of these properties | Yes |
DATE |
| Static_Downhole_Pressure | double Pressure |
Static downhole pressure reading | No |
NUMBER |
| Update_Date | DATE NA |
Date of the most-recent modification to the entity. | No |
DATE |
| Update_User | STRING64 NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
| Version | STRING255 NA |
The form or variant of the entity. | Yes 1 |
VARCHAR2(255) |
| Y_Point_Voltage | double Electric_Potential |
The Voltage as measured at the Y-point on the bottom of the ESP Motor. This measurement is carried to the surface by downhole sensor telemetry. | No |
NUMBER |
| Cardinality | Entity |
|---|---|
| Many | ESP_Sensor_Oper_Pty_Set |
| Link | To Entity | Description | Implementation Technique | Required |
|---|---|---|---|---|
| Measuring_Activity | Generic_Wellsite_Activity | The activity that measured the ESP operating properties | Nullify | No |
| ESP | ESP | The ESP system to which the operating properties belong | Cascade | Yes |