| Name | Ctrl_Panel_Oper_Pty_Set |
|---|---|
| Entity Type | Table |
| Description | The operating properties of a control panel |
| Submodel | Artificial_Lift |
| Entity Scope | Project |
| Primary Key | Id |
| Natural Key | Control_Panel_Id , Start_Date , Existence_Kind , Version |
| Generalizations | Operating_Property_Set , Entity , IT_Object , Tracked_Object |
| Specializations |
| Name | Value Domain / Measurement | Description | Required / Default | Type |
|---|---|---|---|---|
| Control_Panel_Id | Control_Panel |
The control panel to which these operating properties relate | Yes |
NUMBER(38) |
| End_Date | DATE NA |
End date and time of the validity of these properties | No |
DATE |
| Existence_Kind | REF_EXISTENCE_KIND NA |
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. | Yes Actual |
VARCHAR2(64) |
| Final_CT_Ratio | double No_Unit |
The final current transformer ratio identifies the changes (connections and / or turns of wire through the window) made to provide the proper current setting for the system measuring devices | No |
NUMBER |
| Fuse_Capacity_Current | double Electric_Current |
Switchboard Fuse capacity | No |
NUMBER |
| GUID | STRING128 NA |
Globally Unique IDentifier for an instance of a class. This GUID is not generated by the database, but is the GUID used by the application on first access of this object. Use of this property is optional and completely under the control of application developers. | No |
VARCHAR2(128) |
| Id | ID No_Unit |
Unique identifier for this entity. | Yes |
NUMBER(38) |
| Initial_CT_Ratio | double No_Unit |
The initial ratio is current transformer ratio for a given connection, with 1 turn of wire through the window of the current transformer | No |
NUMBER |
| Insert_Date | DATE NA |
Date the entity was created in the repository | No |
DATE |
| Insert_User | STRING64 NA |
The name of the user responsible for the creation of this entity in the repository. | No |
VARCHAR2(64) |
| Measuring_Activity_Id | Generic_Wellsite_Activity |
The activity that measured the Control Panel operating properties | No |
NUMBER(38) |
| Name | ENTITY_NAME NA |
The name given to any object or data item, e.g. Name of Well, Name of Field, etc. | No |
VARCHAR2(255) |
| Original_Source | STRING64 NA |
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" | No |
VARCHAR2(64) |
| Overload_Current | double Electric_Current |
Overload Setting Amperage for Switchboard | No |
NUMBER |
| Overload_Percent | double Percent |
Overload Setting Percentage for Switchboard | No |
NUMBER |
| Produced_By | STRING64 NA |
ID of the activity that was executing when the entity was created, for data created programmatically. | No |
VARCHAR2(64) |
| Remarks | STRING2000 NA |
Any type of remarks added to an entity instance. | No |
VARCHAR2(2000) |
| SDAT_Label | int No_Unit |
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. | No |
NUMBER(10) |
| Source | STRING64 NA |
Name of the person or organization responsible for this entity"s E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. | No |
VARCHAR2(64) |
| Start_Date | DATE NA |
Start date and time of the validity of these properties | Yes |
DATE |
| Underload_Current | double Electric_Current |
Under-load Setting Amperage for Switchboard | No |
NUMBER |
| Underload_Percent | double Percent |
Under-load Setting Percentage for Switchboard | No |
NUMBER |
| Update_Date | DATE NA |
Date of the most-recent modification to the entity. | No |
DATE |
| Update_User | STRING64 NA |
The name of the user responsible for the last modification to this entity. | No |
VARCHAR2(64) |
| VSD_Base_Frequency | double Frequency |
The base operating frequency setting for a VSD | No |
NUMBER |
| VSD_High_Frequency | double Frequency |
The high frequency limit for a VSD | No |
NUMBER |
| VSD_Low_Frequency | double Frequency |
The low frequency limit for a VSD | No |
NUMBER |
| VSD_Operating_Frequency | double Frequency |
The operating frequency setting for a VSD. | No |
NUMBER |
| Version | STRING255 NA |
The form or variant of the entity. | Yes 1 |
VARCHAR2(255) |
| Link | To Entity | Description | Implementation Technique | Required |
|---|---|---|---|---|
| Measuring_Activity | Generic_Wellsite_Activity | The activity that measured the Control Panel operating properties | Nullify | No |
| Control_Panel | Control_Panel | The control panel to which these operating properties relate | Cascade | Yes |