Activity_Facility_Invl


[Columns] [Composed Of] [Referenced By] [Refers To]

General Information

[Next]
Name Activity_Facility_Invl
Entity Type Table
Description A class that shows exactly where a facility is, how it got there, when it got there and what caused it to get there, over a period of time
Submodel Facility
Entity Scope Project
Primary Key Id
Natural Key
Generalizations Entity , IT_Object , Tracked_Object
Specializations Generic_Act_Fac_Invl , Tubular_Utilization


Columns

[Previous] [Next] [Top]
NameValue Domain /
Measurement
DescriptionRequired /
Default
Type
Activity_Id Activity
The activity associated with this particular involvement. It could be the activity that installed the facility, the activity that used the facility etc No
NUMBER(38)
Activity_Role R_Activity_Role
The role that the activity plays in this involvement. It could be the installation activity, the removal activity or utilization activity etc No
VARCHAR2(64)
Activity_Tbl Meta_Entity
Activity type No
VARCHAR2(30)
Base_MD double
Depth
Measured depth to the base of the facility. No
NUMBER
End_Date DATE
NA
End date and time of the validity of this entry. For example for an installation activity this would be the installation date and time and for a utilization activity this would be the end date and time of the period during which the facility is utilized No
DATE
Existence_Kind REF_EXISTENCE_KIND
NA
A reference value that describes the state of existence in the lifecycle of the entity, for example, Planned, Predicted, Required, Simulated, and Actual. Yes
Actual
VARCHAR2(64)
Facility_Id Facility
The facility that is the target of the involvement. For example in an installation involvement it is the facility that is installed Yes
NUMBER(38)
Facility_Role R_Facility_Role
The role that the facility plays in this involvement. It could be a gauge that performs the role of Primary Gauge. No
VARCHAR2(64)
Facility_Tbl Meta_Entity
Facility type Yes
VARCHAR2(30)
GUID STRING128
NA
Globally Unique IDentifier for an instance of a class. This GUID is not generated by the database, but is the GUID used by the application on first access of this object. Use of this property is optional and completely under the control of application developers. No
VARCHAR2(128)
Id ID
No_Unit
Unique identifier for this entity. Yes
NUMBER(38)
Insert_Date DATE
NA
Date the entity was created in the repository No
DATE
Insert_User STRING64
NA
The name of the user responsible for the creation of this entity in the repository. No
VARCHAR2(64)
Name ENTITY_NAME
NA
The name given to any object or data item, e.g. Name of Well, Name of Field, etc. No
VARCHAR2(255)
Original_Source STRING64
NA
The name of the person, Organization or project source that originally provided this entity, e.g. "IHS-EnergyData" or "FinderUpper Stratton Deeper Pool 15" No
VARCHAR2(64)
Position_Id Position
The position at which the facility is located. This should be normally used for facilities installed on the surface (though it can be used for tracking the position of a downhole facility in case of a deviated well). The position of a facility can change over time No
NUMBER(38)
Pressure double
Pressure
The pressure at the facility during its utilization No
NUMBER
Produced_By STRING64
NA
ID of the activity that was executing when the entity was created, for data created programmatically. No
VARCHAR2(64)
Remarks STRING2000
NA
Any type of remarks added to an entity instance. No
VARCHAR2(2000)
SDAT_Label int
No_Unit
Label used by the security system for entitlements. SDAT is Secure Data Access Technology. No
NUMBER(10)
Site_Borehole_Id Borehole
The borehole in which the facility (e.g. A permanent Gauge) is installed or used. In general, this should be used only when a facility is installed or its depth is changed inside a borehole. For activities which utilize a downhole facility, this should be used when the activity involves multiple boreholes. No
NUMBER(38)
Site_Well_Id Well
The well at which the facility is installed. E.g. A Wellhead Facility can be associated to a well using this relationship. No
NUMBER(38)
Source STRING64
NA
Name of the person or organization responsible for this entity"s E and P content and quality. Not the data technologist or IT expert creating the entity, for which see IT_Object.Insert_User and Update_User. No
VARCHAR2(64)
Start_Date DATE
NA
Start date and time of the validity of this entry. For example for an installation activity this would be the installation date and time and for a utilization activity this would be the start date and time of the period during which the facility is utilized No
DATE
Sub_Type Meta_Entity
Sub type of Activity_Facility_Invl No
VARCHAR2(30)
Temperature double
Temperature
The temperature at the facility during its utilization No
NUMBER
Top_MD double
Depth
Measured depth to the top of the facility. No
NUMBER
Update_Date DATE
NA
Date of the most-recent modification to the entity. No
DATE
Update_User STRING64
NA
The name of the user responsible for the last modification to this entity. No
VARCHAR2(64)
Version STRING255
NA
The form or variant of the entity. Yes
1
VARCHAR2(255)


Referenced By

[Previous] [Next] [Top]
From EntityLinkDescriptionImplementation TechniqueRequired
Well_Test_Fluid_Recovery Utilized_Facility The identifier of the facility utilized during the well test. For example, a separator can be utilized during a well test. Restrict No
Well_Test_Interpretation Utilized_Facility The identifier of the facility that was used to collect the data for the interpretation results. E.g. The Primary Pressure Gauge which recorded the pressure data used in interpretation. Restrict No
Well_Test_Trace Utilized_Facility The identifier of the equipment used during the well test to collect the well test trace data (source of the trace). E.g. A downhole pressure gauge used to record Pressures over time. Restrict No


Refers To

[Previous] [Next] [Top]
LinkTo EntityDescriptionImplementation TechniqueRequired
Activity_Role R_Activity_Role The role that the activity plays in this involvement. It could be the installation activity, the removal activity or utilization activity etc Restrict No
Facility Facility The facility that is the target of the involvement. For example in an installation involvement it is the facility that is installed Cascade Yes
Facility_Role R_Facility_Role The role that the facility plays in this involvement. It could be a gauge that performs the role of Primary Gauge. Restrict No
Activity Activity The activity associated with this particular involvement. It could be the activity that installed the facility, the activity that used the facility etc Cascade No
Site_Borehole Borehole The borehole in which the facility (e.g. A permanent Gauge) is installed or used. In general, this should be used only when a facility is installed or its depth is changed inside a borehole. For activities which utilize a downhole facility, this should be used when the activity involves multiple boreholes. Nullify No
Site_Well Well The well at which the facility is installed. E.g. A Wellhead Facility can be associated to a well using this relationship. Nullify No
Position Position The position at which the facility is located. This should be normally used for facilities installed on the surface (though it can be used for tracking the position of a downhole facility in case of a deviated well). The position of a facility can change over time Control No


[Seabed Objects] [Entities in Schema Seabed] [Index]